Commissioning with noise

Analysis:

1. The surface roughness of installation can not meet the requirements, which leads to a negative slack.

2. The gear meshing is not very well. The biggest position of gear run-out is too close.

 

Solutions:

1. Check the surface roughness of installation.

2. Adjust the mesh clearance.